1.7.1 Adjustment
If a leak occurs between the brewer unit and the
permanent filter the tensile force of the brewer needs to
be increased.
The tensile force of the brewer should be set so that no
water is able to leak between the brewer unit (fig. 3-1)
and the permanent filter (fig. 3-3).
The tensile force also ensures that the wiper (fig.
3-4) completely pushes the coffee residue off of the
permanent filter.
See figure 3 for the most important brewer parts:
1. Brewer unit
2. Rubber seal (Art. No. 03375)
3. Permanent filter (Art. No. 03374)
4. Wiper (Art. No. 03380)
5. Tension member
6. Adjustment shim* (Art. No. 03384)
7. Rubber
8. H-frame
9. Tension member adjustment
1. First remove the brewer from the device (see section
8.7.2 for instructions).
2. The tensile force can be set by adding adjustment
shims (fig. 3-6) between the tension member (fig.
3-5) and the H-frame (fig. 3-8).
3. Press the H-frame downwards and take the tension
member out of the recess. Place an adjustment
shim* in the recess and replace the tension member.
CAUTION: adding multiple shims at the same time
can cause excess tensile force and damage the
brewer!
4. In most cases this procedure is sufficient for
repairing leaks. If the brewer unit still leaks fit
another adjustment shim.
5. If the brewer unit still leaks remove the two
adjustment shims and then turn in the tension
member once (clockwise). CAUTION: turning in the
tension member should only be done as a last
resort.
6. If the tensile force is correct but the brewer still leaks
do not increase the tensile force any more! For
further help see chapter 1.7.3 Troubleshooting.